Turned column magnetic magnetic level gauge is based on the
principle of Archimedes (buoyancy), and other principles of
mechanical drive a clever combination of the characteristics of a
developed specifically for liquid level measurement device; which
JG-FO-type is the most Basically a product, and the rest are a
variety of products based on its extension; in the detection level
at the same time we give them more functional When you use this product before we turn first column of magnetic
level gauge works to make a brief introduction. It has a capacity
of the float chamber we call the main pipe or casing, which through
the flange and the container or other interfaces to form a
connected device; so that it is the body cavity surface and the
liquid inside the container is the same height, so Chamber of the
float will rise and fall with the liquid container and lift; this
time we can not see the liquid level, so we installed the outside
cavity of a turned column display, because when we are floating in
the manufacture of float Part of the ball sinking into the liquid
and floating to the junction of installed magnets, lifting it with
the float with the surface, its magnetic shell passed through the
column turned the monitor, and promote the magnetic column flip
turn 180 °; due to the magnetic translation Column is red, white,
cylindrical synthetic cylinder two and a half, so after turning
180turn towards the outside of column display will change color
(red below the liquid level above white), the junction of the two
colors is the height of liquid Column in turn controlled level gauge magnetic switch based on the
increase, while monitoring the magnetic switch signal level can be
used to control or alarm level; FET-type level gauge in turn the
basis of column Added to the 4 ~ 20mA sensor transmitter, liquid
level in the field, while monitoring changes in the level through
the transmission sensors, cables and instruments reached the
control room, remote monitoring and control | Key words: | Liquid level measurement and control, interface measurement and
control | Measuring range[L]: (Center distance of the upper and lower flanges) | Users make | | Flange specifications: | DN20 PN1.0RF Or user made | Wetted: 321 or 304 stainless steel 316L stainless steel PVC plastic PTFE lined stainless steel | 321 or 304 stainless steel Or users | Medium density[g/cm3]: (Made by the user) | ≥0.53 | | Temperature[℃]: | ≤80℃,≤150℃,≤350℃ | | Work stress[MPa]: | 0~4.0MPa | | Output signal: | Heating mode: steam heating means heating cable heating mode Users make) | | Applied voltage / current: |
|