JGLU gas vortex flowmeter series is mainly used for medium industrial pipe fluid flow measurement of steam, steam vortex flowmeter features low pressure loss, measuring range, high precision in the measurement conditions are not nearly the volume density of the fluid flow , Pressure, temperature, viscosity and other parameters. No moving mechanical parts, so high reliability and little maintenance. Long-term stability of the instrument parameters. Gas flowmeter using piezoelectric stress sensors, high reliability, can be -20~ +250operating temperature range. With analog standard signal, but also digital pulse signal output, easily supporting the use of computers and other digital systems is a more advanced and ideal flow meter 1、Works Triangle set in the steam flow cylindrical bluff body, alternately from both sides of the bluff body to generate a regular vortex, this vortex is called Carmen vortex, as shown, the vortex downstream of the bluff body listed in the non-symmetrically Order The occurrence frequency of the vortex set f, the average flow rate of the measured medium, the bluff body surface facing the flow width d, the body of the path to D, you can get the following relation: f=SrU1/d=SrU/md1) Where U1 - the average velocity on both sides of the bluff bodym/s Sr--Strouhal number m--Segment Area on both sides of the bluff body and the pipe cross-sectional area ratio Pipe volume flowqv qv=D2U/4=D2mdf/4Sr(2) K=f/qv=[D2md/4Sr]-1(3) Where K - the instrument flow coefficient, the number of pulses / m3(P/m3) K addition to the bluff body, the relevant geometry of the pipeline, but also with the Strouhal number related. Strouhal number of dimensionless parameters, it is with the bluff body shape and Reynolds number on Figure 2 shows the cylindrical bluff body of the Strouhal number and the pipe Reynolds number diagram. The figure shows that in ReD = 2104 ~ 7106 range, Sr can be considered as a constant, which is the normal operating range instrument. When the measurement of gas flow, VSF formula for the flow meter (4) Figure 2 Relationship between Strouhal number and Reynolds number curve Where qVn, qV - were under standard conditions (0oC or 20oC,
101.325kPa) and the volume of traffic conditionsm3/h PnP--Respectively, under standard conditions and conditions for the absolute pressurePa TnT--Respectively, under standard conditions and conditions of the thermodynamic temperatureK ZnZ--Respectively, under standard conditions and conditions for the gas compressibility Can be seen from the above equation, VSF output pulse frequency signal from fluid properties and composition changes, that instrument coefficient in a certain Reynolds number range, and only with the bluff body shape and size of the pipe and so on. But as the material balance and energy flow in the measurement of mass flow to be detected, then the flow meter should also monitor the volume of the output signal flow and fluid density, fluid properties and composition of the flow measurement or have a direct impact Gas flowmeter is based on the vortex principle Carmen Measurement
of fluid flow in closed conduits new flow meter. Media because of
its good ability to adapt, without direct measurement of
temperature and pressure compensation can be steam, air, gas,
water, liquid volume flow conditions, with temperature and pressure
sensor measures the standard volume flow and mass flow conditions,
is to cut expenditure Flowmeter ideal alternative To improve the high temperature gas flowmeter and anti-vibration performance, the company recently developed a JGLUG improved vortex flow sensors, because of its unique structure and selection of materials so that the sensor at high temperature (350 ℃), high vibration (≤ 1g) use of harsh conditions In practice, the maximum flow rate is often much lower than the upper limit of the instrument, as the load changes, the minimum flow rate and often lower than the lower limit of the instrument, meters are not working in its optimum operating segment, in order to solve this problem , commonly used in the measurement at the reduced diameter to improve the measurement at the flow rate, and smaller-diameter instrument to facilitate selection of the measurement instrument, but this must be adjustable means between adjustable tube and instrument over a length of straight pipe section 15D to Rectifier, the processing, installation is not easy. Our company has developed a vertical section of the shape of arc rectifier LGZ adjustable, with a rectifier to improve the flow and velocity distribution change multiple roles, its structure, small size, process tube diameter of only 1 / 3, one made with the vortex flowmeter Not only do not need to add another section of straight pipe, you can also reduce the process tube |
Do you want to show products of your own company? Join FREE now!